Ensure the safety and reliability of your heating system with this premium Flame Rollout Switch featuring a manual reset. Designed as a critical safety limit for gas-fired furnaces and boilers, this sensor detects abnormal heat levels—specifically 'flame rollout'—where flames escape the combustion chamber. When temperatures reach the 290°F threshold, the switch interrupts the electrical circuit to the gas valve, shutting down the system to prevent potential fire hazards or equipment damage. Because this is a manual reset model, it requires a physical inspection of the HVAC unit before the system can be restarted, providing an essential layer of protection for homeowners and property managers. Ideal for routine furnace maintenance or emergency HVAC repairs, this high-temperature limit switch is a vital component for maintaining a safe indoor environment.
Type: Flame Rollout Switch
Size: Small
Application: Used in residential and commercial gas furnaces, boilers, and water heaters as a safety limit control.
Specifications: Trip Temperature: 290°F; Reset Type: Manual; Circuitry: Normally Closed (NC); Component Type: High-limit safety sensor.
Type: Flame Rollout Switch
Size: Small
Application: Used in residential and commercial gas furnaces, boilers, and water heaters as a safety limit control.
Specifications: Trip Temperature: 290°F; Reset Type: Manual; Circuitry: Normally Closed (NC); Component Type: High-limit safety sensor.